Loading...

Levitronix®PuraLev®
Low Shear Single-Use
Flow Controllers
for Bioprocessing

Single-Use Pump Head DCP-30.2-SF1-G25 (Sterile Fittings)

Max. Flow (l/min)
7.7
Max. diff. Pressure (bar)
1
Fitting Size
3/8"
Applied Gamma Dosage
≥ 25 kGy
Max. Liquid Temperature
60°C / 140°F

Single-Use Pump Head DCP-200.3-SF1-G25 (Sterile Fittings)

Max. Flow (l/min)
21
Max. diff. Pressure (bar)
2
Fitting Size
1/2”
Applied Gamma Dosage
≥ 25 kGy
Max. Liquid Temperature
60°C / 140°F

Single-Use Pump Head DCP-30.1-G25

Max. Flow (l/min)
7.7
Max. diff. Pressure (bar)
1
Fitting Size
3/8"
Applied Gamma Dosage
≥ 25 kGy
Max. Liquid Temperature
60°C / 140°F

Single-Use Pump Head DCP-200.3-G25

Max. Flow (l/min)
21
Max. diff. Pressure (bar)
2
Fitting Size
1/2”
Applied Gamma Dosage
≥ 25 kGy
Max. Liquid Temperature
60°C / 140°F

Single-Use Pump Head DCP-200.2-G25

Max. Flow (l/min)
21
Max. diff. Pressure (bar)
2
Fitting Size
1/2”
Applied Gamma Dosage
≥ 25 kGy
Max. Liquid Temperature
60°C / 140°F

Single-Use Pump Head DCP-30.2-G25

Max. Flow (l/min)
7.7
Max. diff. Pressure (bar)
1
Fitting Size
3/8"
Applied Gamma Dosage
≥ 25 kGy
Max. Liquid Temperature
60°C / 140°F
Spare Part
Spare Part

Single-Use Pump Head DCP-30.2

Max. Flow (l/min)
7.7
Max. diff. Pressure (bar)
1
Fitting Size
3/8"
Max. Liquid Temperature
60°C / 140°F
Spare Part

Single-Use Pump Head DCP-30.1

Max. Flow (l/min)
7.7
Max. diff. Pressure (bar)
1
Fitting Size
3/8"
Max. Liquid Temperature
60°C / 140°F
Spare Part
Spare Part

Single-Use Pump Head DCP-200.3

Max. Flow (l/min)
21
Max. diff. Pressure (bar)
2
Fitting Size
1/2”
Max. Liquid Temperature
60°C / 140°F
Spare Part

Single-Use Pump Head DCP-200.2

Max. Flow (l/min)
21
Max. diff. Pressure (bar)
2
Fitting Size
1/2”
Max. Liquid Temperature
60°C / 140°F

Single-Use Sensor LFS-03SU-Z-F1-SC1-G25

Flow Range Sensor (l/min)
0.006 - 0.8 (Accuracy of +/- 1 %)
Max. Viscosity (mm²/s)
0.3-40 mm²/s
Max. Pressure (bar)
5
Applied Gamma Dosage
≥ 25 kGy
Max. Liquid Temperature
2 - 60 °C

Single-Use Sensor LFS-03-SU-Z-F1-SC1

Flow Range Sensor (l/min)
0.006 - 0.8 (Accuracy of +/- 1 %)
Max. Viscosity (mm²/s)
0.3-40 mm²/s
Max. Pressure (bar)
5
Max. Liquid Temperature
2 - 60 °C

Single-Use Sensor LFS-06-SU-Z-F1-SC1

Flow Range Sensor (l/min)
0.075 - 8 (Accuracy of +/- 1 %)
Max. Viscosity (mm²/s)
0.3-40 mm²/s
Max. Pressure (bar)
5
Max. Liquid Temperature
2 - 60 °C

Single-Use Sensor LFS-06SU-Z-F1-SC1-G25

Flow Range Sensor (l/min)
0.075 - 8 (Accuracy of +/- 1 %)
Max. Viscosity (mm²/s)
0.3-40 mm²/s
Max. Pressure (bar)
5
Applied Gamma Dosage
≥ 25 kGy
Max. Liquid Temperature
2 - 60 °C

Single-Use Sensor LFS-06SU-Z-F1-G25

Flow Range Sensor (l/min)
1.75 - 8 (Accuracy of +/- 1 %)
Max. Viscosity (mm²/s)
0.3-40 mm²/s
Max. Pressure (bar)
5
Applied Gamma Dosage
≥ 25 kGy
Max. Liquid Temperature
2 - 60 °C
Spare Part

Single-Use Sensor LFS-06-SU-Z-F1

Flow Range Sensor (l/min)
1.75 - 8 (Accuracy of +/- 1 %)
Max. Viscosity (mm²/s)
0.3-40 mm²/s
Max. Pressure (bar)
5
Max. Liquid Temperature
2 - 60 °C

Single-Use Sensor LFS-03SU-Z-F1-G25

Flow Range Sensor (l/min)
0.035 - 0.8 (Accuracy of +/- 1 %)
Max. Viscosity (mm²/s)
0.3-40 mm²/s
Max. Pressure (bar)
5
Applied Gamma Dosage
≥ 25 kGy
Max. Liquid Temperature
2 - 60 °C
Spare Part

Single-Use Sensor LFS-03-SU-Z-F1

Flow Range Sensor (l/min)
0.035 - 0.8 (Accuracy of +/- 1 %)
Max. Viscosity (mm²/s)
0.3-40 mm²/s
Max. Pressure (bar)
5
Max. Flow (l/min)
0.8
Max. Liquid Temperature
2 - 60 °C

Single-Use Sensor LFS-10SU-Z-SC1-G25

Flow Range Sensor (l/min)
0.75 - 20 (Accuracy of +/- 1 %)
Max. Viscosity (mm²/s)
0.3-40 mm²/s
Applied Gamma Dosage
≥ 25 kGy
Fitting Size
1/2"
Spare Part

Single-Use Sensor LFS-10SU-Z-SC1

Flow Range Sensor (l/min)
0.75 - 20 (Accuracy of +/- 1 %)
Max. Viscosity (mm²/s)
0.3-40 mm²/s
Fitting Size
1/2"
Max. Liquid Temperature
2 - 60 °C

Single-Use Sensor LFS-06SU-Z-SC1-G25

Flow Range Sensor (l/min)
0.075 - 8 (Accuracy of +/- 1 %)
Max. Viscosity (mm²/s)
0.3-40 mm²/s
Fitting Size
3/8"
Applied Gamma Dosage
≥ 25 kGy
Max. Liquid Temperature
2 - 60 °C
Spare Part

Single-Use Sensor LFS-10SU-Z-G25

Flow Range Sensor (l/min)
4.7 - 20 (Accuracy of +/- 1 %)
Max. Viscosity (mm²/s)
0.3-40 mm²/s
Applied Gamma Dosage
≥ 25 kGy
Fitting Size
1/2"
Spare Part

Single-Use Sensor LFS-06SU-Z-G25

Flow Range Sensor (l/min)
1.75 - 8 (Accuracy of +/- 1 %)
Max. Viscosity (mm²/s)
0.3-40 mm²/s
Applied Gamma Dosage
≥ 25 kGy
Fitting Size
3/8"
Spare Part

Single-Use Sensor LFS-10SU-Z

Flow Range Sensor (l/min)
4.7 - 20 (Accuracy of +/- 1 %)
Max. Viscosity (mm²/s)
0.3-40 mm²/s
Fitting Size
1/2"
Max. Liquid Temperature
2 - 60 °C
Spare Part

Single-Use Sensor LFS-06SU-Z-SC1

Flow Range Sensor (l/min)
0.075 - 8 (Accuracy of +/- 1 %)
Max. Viscosity (mm²/s)
0.3-40 mm²/s
Fitting Size
3/8"
Max. Liquid Temperature
2 - 60 °C
Spare Part

Single-Use Sensor LFS-06SU-Z

Flow Range Sensor (l/min)
1.75 - 8 (Accuracy of +/- 1 %)
Max. Viscosity (mm²/s)
0.3-40 mm²/s
Fitting Size
3/8"
Max. Liquid Temperature
2 - 60 °C

Integrated Pump Driver IFD-100.6-02 (Stand-Alone Model)

Service/Control Interface
Button Control Mode

Integrated Pump Driver IFD-100.5-02 (EasyConnect Model)

Service/Control Interface
RS485 with Modbus protocol and PLC Interface