100-30479
                        
                Clamp-On Sensor LFSC-i19X-001
                            Availability on request                        
                        
                    
                            Flow Range Sensor (l/min)
                            0 - 50 (Accuracy of +/- 1.5 %)
                        
                                            
                            Max. Viscosity (mm²/s)
                            0.5 – 100 mm² /s
                        
                                            
                            Tubing Size (ID x OD)
                            3/4" x 1/2"
                        
                                            
                            Max. Liquid Temperature
                            10 - 60 °C
                        
                                    
                    The LEVIFLOW® LFSC-D clamp-on sensor is designed for non-invasive flow measurements of high purity fluids with PFA tubing. Two piezoelectric transducers generate and receive ultrasonic waves. When flow is present, the with-stream wave is accelerated, and the against-stream wave is slowed down. The difference in transit time is proportional to the velocity of the fluid.
            
Default activated calibration set is Silicone Pharma at 37°C water temperature. Other calibrations sets can be chosen with Levitronix® Service Software or with user panel LUI-B.1.
Specifications
| Flow Range Sensor (l/min) | 0 - 50 (Accuracy of +/- 1.5 %) | 
|---|---|
| Max. Pressure (bar) | 5 | 
| Max. Viscosity (mm²/s) | 0.5 – 100 mm² /s | 
| Tubing Size (ID x OD) | 3/4" x 1/2" | 
| Fitting Type | Tube | 
| Max. Liquid Temperature | 10 - 60 °C | 
| Power | 24 VDC | 
| Service/Control Interface | RS485 with Modbus protocol | 
 
                 
                                         
                                         
                                         
                                         
                                        